The Edan iM3 Vital Signs Monitor features cutting-edge technology for monitoring vital signs. Engineered to enhance daily usability, its internal Wi-Fi capabilities, streamlined data storage, and review make extremely user friendly and ideal for the simulation environment.
Features:
- Supports hard key and knob operation
- Unique cable-receiving design
- Continuous Monitoring/Spot/Round Modes
- MEWS/EWS/NEWS score system
- Integrates with Point Click Care with VitalsXChange
- Integrates with Health o meter® Professional Scales
- Standard Parameters: SpO2, NIBP, PR
- Optional Parameters: Nellcor OxiMax™ SpO2, SunTech NIBP, Covidien Oral Temp, Infrared Ear Temp, Quick Oral Temp, Non-Contact Temp, and Exergen Temporal Temp
- Compatible with MT-206 Rolling Stand with basket (02-43-0463, sold separately)
Innovative Design:
- Lightweight, ultra slim and portable design
- 8" Color TFT touch screen
- Proprietary Round Mode made for fast paced environments
- Barcode scanner support
- USB, OTG, LAN, & DCHP
- Built in Wi-Fi
- 360-Degree alarm light
Adaptive Work Modes:
- Round Mode:
- Designed to make daily use more efficient
- Easily upload data through Wi-Fi to your EMR
- Features color-coded list
- Preset and save resident names and room numbers
- Up to 1,000 names can be added at once
- Monitoring Mode:
- Designed for continuous patient monitoring
- Real-time data, alarms, and trends
- Spot Mode:
- Designed for spot-check applications
- Real-time vitals
Includes:
- SPO2 Finger Sensor, Adult, 1m, reusable, DB9
- Adult Cuff (27cm–35cm)
- NIBP Tube (3m) with connector
- Power Cord (USA Standard)
- Rechargeable Lithium-ion Battery
- Potential Equalization Conductor
- SPO2 7-PIN Extension Cable, 2m
- (200) Covidien Oral Temp Probe Covers
- Covidien Oral Temp Kit
- Covidien Oral Probe
Specifications:
- Dimensions: 10.3 H × 6.3" W × 6.5" D
- Weight: approx. 5.5 lb.
- Color TFT LCD display: 8"
- Resolution: 800 × 600
- Power Supply: 100V-240 V~, 50 Hz/60 Hz
- Current: 0.7 A-0.35 A; Fuse: T2.5AH, 250VAC
- Interfaces:
- (1) USB Port
- (1) Micro USB Port
- (1) Network Interface
- Nurse Call: Micro USB Port
- Data Storage:
- Monitor Mode:
- Trend Graph: 1hr, 1s resolution Table: 120 hrs, 1m resolution Alarm/ Monitoring
- Event Data: Up to 200 sets
- NIBP Review: 1200 sets
- Round Mode:
- Round Record: Up to 800K sets SpO2: ≤20 sets for single patient NIBP: ≤20 sets for single patient TEMP: ≤20 sets
- Spot Checking Mode: Storage data maximally contains 16 million sets of spot-checking data for multiple patients
- Monitor Mode:
- NIBP:
- Technique: Oscillometry
- Mode: Manual, Auto, Continuous, Measuring Interval in AUTO Med
- (Unit: minutes): 1/2/3/4/5/10/15/30/60/90/120/180/240/360/480
- Continuous 5 min. interval in 5s measuring parameter: SYS, DIA, MAP, Measuring Range
- Adult Mode:
- SYS: 25 mmHg to 290 mmHg
- DIA: 10mmHg to 250 mmHg
- MAP: 15 mmHg to 260 mmHg
- Pediatric Mode:
- SYS: 25 mmHg to 240 mmHg
- DIA: 10 mmHg to 200 mmHg
- MAP: 15 mmHg to 215 mmHg
- Neonate Mode:
- SYS: 25 mmHg to 140 mmHg
- DIA: 10 mmHg to 115 mmHg
- MAP: 15 mmHg to 125 mmg
-
- Alarm Type: SYS, DIA, MAP, PR (NIBP)
- Cuff Pressure Measuring Range: 0 mmHg to 300 mmHg
- Pressure Resolution: 1 mmHg
- Maximum Mean Error: ±5 mmHg
- Maximum Standard Deviation: 8 mmHg
- Maximum Measuring Period: Adult/Pediatric: 120s
- Neonate: 90s
- Typical Measuring Period: 20s to 35s (depends on HR/motion disturbance)
- Overpressure Protection:
- Adult: 297 mmHg±3 mmHg
- Pediatric: 245 mmHg±3 mmHg
- Neonatal: 147 mmHg±3 mmHg
- PR:
- Measuring Range: 40 bpm – 240 bpm
- Accuracy: ≥ 3 bpm or 3.5%, whichever is greater
- SPO2:
- Measuring Range: 0% to 100%
- Resolution: 1%
- Data update period: 1s
- Accuracy:
- Adult/ Pediatric: ±2% (70% to 100% SpO2
- Undefined (0% to 69% SpO2)
- Neonate: ±3% (70% to 100% SpO2
- Undefined (0% to 69% SpO2)
- Measuring Range: 0-10
- Perfusion Index:
- Resolution: 1
- Pulse Rate:
- Measuring Range: 25 – 300 bpm
- Resolution: 1 bpm
- Accuracy: ≥2 bpm
- Temperature (F3000 Module: Covidien Oral Temp):
- Measuring Range: 30 C-43 C
- Prediction Measurement: 35 C~43 C
- Color Mode Prediction: 35 C~43 C
- Sensor Type: Oral/Axillary/Rectal Resolution: 0.1 C
- Accuracy: Monitor/ Predictive Mode: ±0.1 C Quick
- Predictive Mode: ±0.3 C
- Typical Measurement:
- Oral: Quick Predictive Mode: 3-5 s (non-fever temps); 8-10s (fever temps)
- Rectal: 10-14s; Monitoring mode (all sites): 60-120s